Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'iron oxide' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'iron oxide' found in 6 terms [] and 34 definitions []
previous     16 - 20 (of 40)     next
Result Pages : [1 2]  [3 4 5 6 7 8]
Searchterm 'iron oxide' was also found in the following service: 
spacer
News  (25)  
 
FerumoxtranInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: Ami 227, generic name: Ferumoxtran, (USPIO)
Ferumoxtran is a substance of the class of ultrasmall superparamagnetic iron oxide used as a lymph node specific contrast agent for MRI.
See also Combidex®, Sinerem® and Ultrasmall Superparamagnetic Iron Oxide.
Partner(s): Cytogen Corporation, National Cancer Institute. An approvable letter was received from the U.S. Food and Drug Administration for Combidex in June 2000. Advanced Magnetics, Inc. has submitted a complete response to the approvable letter received from the U.S. Food and Drug Administration, which was accepted by the FDA and assigned a user fee goal date of March 30, 2005. In Europe, a Dossier (the European equivalent of a NDA) was submitted by Advanced Magnetics' European partner, Guerbet SA, to the European Medicines Evaluations Agency in December 1999. (Sinerem® is the brand name for this USPIO in Europe manufactured by Guerbet, Combidex® by Advanced Magnetics for the U.S. market)
Advanced Magnetics, Inc. changed its name in July 2007 to AMAG Pharmaceuticals Inc.
spacer
 
Further Reading:
  Basics:
Superparamagnetic Iron Oxide–enhanced MR Imaging of Head and Neck Lymph Nodes1
Comparison of Two Superparamagnetic Viral-Sized Iron Oxide Particles Ferumoxides and Ferumoxtran-10 with a Gadolinium Chelate in Imaging Intracranial Tumors
2002   by www.ajnr.org    
  News & More:
Optimized Labelling of Human Monocytes with Iron Oxide MR Contrast Agents
Sunday, 30 November 2003   by rsna2003.rsna.org    
SPL Medical starts clinical trial with contrast agent ferrotran
Tuesday, 11 February 2020   by www.radboudumc.nl    
SPL Medical receives approval for Clinical Trial with contrast agent Ferrotran® in 10 top radiology centers.
Friday, 15 March 2019   by ferrotran.com    
Ultrasmall Superparamagnetic Particles of Iron Oxide-enhanced in vivo MRI of human atherosclerotic plaques.(.pdf)
MRI Resources 
Safety pool - DICOM - Image Quality - Stimulator pool - MRI Training Courses - Claustrophobia
 
LiposomesInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Generic name: Liposomes, central moiety: different, contrast effect: paramagnetic, distribution: different
Liposomes are lipid containing nanoparticles, or fat molecules, surrounding a water core. Liposomes were the first type of nanoparticles created to be used as carriers for lipophilic MRI contrast agents with novel characteristics.
Liposomes loaded with gadolinium-containing chelates have potential as blood pool agents, caused by modifications of the surface (e.g., with polyethylene glycol) leading to longer blood retention times.
The incorporation of contrast agents into either the the bilayer membrane or the aqueous inner cavity is possible. These MRI contrast agents has been used to image the lymph nodes using liposomes containing Gd-DTPA as well as dextran coated iron oxide particles.
To image the liver or the hepatobiliary system, liposomes containing Gd-HPDO3A, or MnDPDP, have been tested.
Liposomes containing gadolinium were conjugated to antibodies and targeted to a specific organ system.
A method of targeting tumors with ultrasound that also uses MRI to watch the cell destroying, uses liposomes loaded with cytotoxic drugs and also with gadolinium to make them show up in MRI. As well as used as an imaging technique, ultrasound can also be used to destroy cancer cells. Once the drugs have been administered, focusing the ultrasound on the target area makes blood vessels permeable. The liposomes leak out of the blood vessel into the target area, watched by MRI, where the cytotoxic drug can then go to work.

See also Memosomes, Superparamagnetic Iron Oxide, Classifications, Characteristics, etc. and Mangafodipir Trisodium.
spacer

• View the DATABASE results for 'Liposomes' (6).Open this link in a new window


• View the NEWS results for 'Liposomes' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Novel Agent for Lymph Node Imaging and Targeted Gene Therapy
1997   by cbcrp.org.127.seekdotnet.com    
DELIVERY AND ACTIVATION OF CONTRAST AGENTS FOR MAGNETIC RESONANCE IMAGING(.pdf)
   by thesis.library.caltech.edu    
New MRI Contrast Agent Under Development
Friday, 16 January 2009   by www.medgadget.com    
New Method Combines MRI, HIFU, Temperature-Sensitive Liposomes for Chemo Delivery Directly to Tumor
Wednesday, 9 February 2011   by www.medgadget.com    
  News & More:
Specialized MRI sensor can detect light deep within tissues
Thursday, 22 December 2022
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Molecular Magnetic Resonance Imaging(.pdf)
2005   by www.medical.siemens.com    
MRI Resources 
PACS - Mobile MRI - Movies - Corporations - Crystallography - Resources
 
Molecular Imaging
 
Molecular Imaging is a new diagnostic discipline to visualize biological processes.
Molecular magnetic resonance imaging (mMRI) offers the potential to image tissues at the cellular and subcellular level. Targeted MR contrast agents enhance the diagnostic specificity and range of molecular magnetic resonance imaging.
Other modalities that can be used for noninvasive molecular imaging:
•
Ultrasound;
•
optical imaging;
•
positron emission tomography (PET);
•
single photon emission computed tomography (SPECT).


See also Nanoparticle, Monocrystalline Iron Oxide Nanoparticle, Polycrystalline Iron Oxide Nanoparticles, Liposomes, Monoclonal Antibodies, Bimodal Imaging, Tumor Specific Agents, and Intracellular Contrast Agents.
spacer

• View the DATABASE results for 'Molecular Imaging' (10).Open this link in a new window


• View the NEWS results for 'Molecular Imaging' (28).Open this link in a new window.
 
Further Reading:
  Basics:
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Molecular Magnetic Resonance Imaging(.pdf)
2005   by www.medical.siemens.com    
  News & More:
Smarter MRI diagnosis with nano MRI lamp
Monday, 6 February 2017   by www.eurekalert.org    
Molecular MRI technique gives early indication of cancer treatment effectiveness
Monday, 11 April 2016   by www.healthimaging.com    
Molecular imaging and radiochemistry: the importance of instrumentation. An interview with Professor Bjorn Wangler
Thursday, 4 February 2016   by www.news-medical.net    
Positron Emission Tomographic Imaging in Stroke
Monday, 28 December 2015   by www.ncbi.nlm.nih.gov    
Potential and Limitations of Oxygen-17 MR Perfusion Measurements
Monday, 1 March 2004   by www.case.edu    
Searchterm 'iron oxide' was also found in the following service: 
spacer
News  (25)  
 
NC100150 InjectionInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: NC100150, PEG-feron, generic name: Feruglose, preliminary trade name: Clariscanâ„¢
NC100150 injection is the code name for an USPIO (ultrasmall superparamagnetic iron oxide) MRI contrast agent under development. Microvessel permeability depends on functional and morphologic characteristics of cancer vessels and on physicochemical properties of the injected contrast medium molecule.
USPIO particles have a favorable pharmacological and tolerance profile and are being tested clinically of the potential for the quantitative characterization of tumor microvasculature and specifically for measures of the microvessel permeability. Iron-based products take advantage of their large molecular size, which prevents diffusion into body tissues. These agents are disposed of by the liver and spleen as particulate matter.
NC100150 Injection (Nycomed Amersham, Amersham Health ) consists of USPIO particles that are composed of single crystals (4- to 7-nm diameter) and stabilized with a carbohydrate polyethylene glycol (PEG) coat. The iron oxide particles have to be suspended in an isotonic glucose solution. The final diameter of an USPIO particle is approximately 20 nm. Blood pool half-life is more than two hours in humans; the particles are taken up by the mononuclear phagocyte system and distributed mainly to the liver and spleen.
NC100150 would compete with the contrast agents Ferumoxytol from AMAG Pharmaceuticals, Inc. and Vasovistâ„¢ from EPIX Pharmaceuticals, Inc., but at this time the development of NC100150 Injection/Clariscan™ is discontinued.
spacer

• View the DATABASE results for 'NC100150 Injection' (5).Open this link in a new window


• View the NEWS results for 'NC100150 Injection' (2).Open this link in a new window.
MRI Resources 
MRI Reimbursement - Services and Supplies - Databases - Societies - MRI Technician and Technologist Schools - Portals
 
Supravistâ„¢InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: SHU 555 C, preliminary trade name: Supravistâ„¢
An ultrasmall superparamagnetic iron oxide under development as a positive enhancing blood pool agent (MRI contrast agent phase III, Bayer Schering Pharma AG). Supravist™ can be administered as an iv. bolus up to doses of 80 μmol/kg.

See also Ultrasmall Superparamagnetic Iron Oxide and Blood Pool Agents.
spacer

• View the DATABASE results for 'Supravist™' (3).Open this link in a new window

MRI Resources 
Shoulder MRI - MRI Training Courses - Shielding - Portals - Used and Refurbished MRI Equipment - Pacemaker
 
previous      16 - 20 (of 40)     next
Result Pages : [1 2]  [3 4 5 6 7 8]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 4 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]